Part M Bathroom Requirements: What Homeowners Need to Know
What Part M means for a home bathroom or WC in Wales and England, when it applies to a renovation, and the key WC dimensions to plan around.
Part M Bathroom Requirements: What Homeowners Need to Know

Part M of the Building Regulations covers access to and use of buildings. For a home bathroom in Cardiff or the Vale of Glamorgan, the short answer is that Part M does not force you to make an existing bathroom wheelchair-accessible when you renovate it. What it does require is that you do not make a ground-floor WC less accessible than it was. The tougher dimensions people search for, such as 2200 mm × 1500 mm, belong to accessible toilets in public and non-domestic buildings, though they are a useful guide if you are planning a bathroom for a wheelchair user. We fit bathrooms, wet rooms and WCs across Cardiff and the Vale, so this is the version we would give a customer before quoting.
TL;DR
- In Wales, Approved Document M does not apply to extensions or material alterations of a dwelling, but your work must leave the home no less accessible than before.
- If your house was built after 1999, its ground-floor WC was designed for visiting wheelchair users. Do not remove it or make it less accessible in a re-fit.
- Swapping units and fittings generally needs no approval. Adding a bathroom where there was none, or altering drainage or electrics, may need building control.
- A fully wheelchair-accessible toilet room is 2200 mm deep × 1500 mm wide, with a 1500 × 1500 mm turning space.
- Wales and England have separate rules, so check which document applies to your property.
Table of Contents
- Does Part M apply to your bathroom renovation?
- WC dimensions: what the figures mean
- Door, rails and alarm: the accessible toilet checklist
- Public buildings: what changed recently
- Can a toilet open straight off a kitchen?
- Approval, ventilation and who signs it off
- A worked example
- Perspective
- Planning your bathroom with us
- FAQ
- Sources
Does Part M apply to your bathroom renovation?
In Wales, Approved Document M applies to newly built dwellings and to non-domestic buildings. It does not apply to extensions or material alterations of an existing dwelling. Even so, the work must leave the building no more unsatisfactory than before.
In practice that means:
- Refitting with new units. GOV.WALES says refitting a kitchen or bathroom with new units and fittings does not generally need building regulations approval. Drainage or electrical work that forms part of the refit may.
- Creating a new bathroom. If a bathroom goes into a room that never had one, approval is likely to be needed for ventilation, drainage, structural stability, electrical and fire safety.
- A ground-floor WC. GOV.WALES states that any dwelling built after 1999 has a ground-floor WC designed for visiting wheelchair users. In a re-fit the WC should not be removed or made less accessible, and altering it may need a building regulations application.
The Welsh guidance explains the aim: to let people with reducing mobility stay in their own homes for longer, not to guarantee fully independent living for everyone.
Wales and England are not the same
England has its own Approved Document M Volume 1. It sets three categories for dwellings: visitable (category 1), accessible and adaptable (category 2) and wheelchair user (category 3). Categories 2 and 3 apply only where planning permission requires them. Every new dwelling in England must have a WC and basin on the entrance storey, with the door opening outwards, and in larger homes an installed or potential level-access shower too. If your property is in Cardiff or Barry, the Welsh document is the one that governs.
WC dimensions: what the figures mean
Most searches for “Part M WC dimensions” are after the accessible toilet figures. These come from Approved Document M Volume 2, which covers buildings other than homes. They are a sound benchmark if you are designing for a wheelchair user, but they are not a legal test for an ordinary home refit.
| Item | Figure |
|---|---|
| Wheelchair-accessible unisex toilet room | 2200 mm deep × 1500 mm wide |
| Turning space | 1500 × 1500 mm |
| Transfer space beside the WC | 1000 mm from the WC centre line to the opposite wall |
| WC seat height | 480 mm |
| Horizontal grab rail height | 680 mm |
| Basin rim | 720-740 mm |
These come from a specialist’s summary of Volume 2 diagrams 18 and 19. The same source warns that older drawings often show 2000 mm depth, which is 200 mm short of the current figure. Where the accessible toilet is a building’s only toilet, the width rises to 2000 mm.
For a home designed as a wheelchair-user dwelling, Volume 1 asks for a bathroom with a minimum 1500 mm clear turning circle. In homes with five or more bedspaces, it asks for both a usable bath and a level-access shower.

Walls that can take grab rails
Volume 1 expects walls, ducts and boxings around the WC, bathroom and shower room to be strong enough to support grab rails and seats, up to a load of 1.5 kN/m². That is cheap to do while walls are open and costly to retrofit, which is a good reason to think about it during a renovation even if you do not need rails today.
Door, rails and alarm: the accessible toilet checklist
The following details apply to accessible toilets in public settings, and they are useful for anyone planning a wheelchair-friendly room.
- Door. East Sussex Building Control guidance gives a 900 mm clear opening, 300 mm clear space beside the leading edge, lever handles and a lock operable with a closed fist, and an emergency release outside. Outward-opening doors with a horizontal closing bar inside are preferred.
- Rails. Fold-down rails should have friction hinges so they can be lowered effortlessly from a seated position.
- Floor and contrast. A non-slip floor and visually contrasting rails and fittings.
- Alarm cord. Public accessible toilets use a red emergency cord reaching to within 100 mm of the floor. A BBC report from February 2025 described a reporter stuck on a toilet floor for six hours after a cord snapped, which shows why the cord needs to reach the floor and be properly maintained.
Is a pull cord a legal requirement? Part M sets alarm provisions for accessible toilets in non-domestic buildings. There is no equivalent requirement for the bathroom in a private home, though a cord or alarm is a sensible addition for a household member with limited mobility.
Public buildings: what changed recently
If you own or manage a commercial property as well as a home, the rules differ. In England, the 2024 amendments, in force from 1 October 2024, say a wheelchair-accessible unisex toilet should always be provided in addition to accessible accommodation in separate-sex washrooms. It must not be used for baby changing. In Wales, amendments from 3 January 2023 require at least one Changing Places toilet in retail premises of 5,000 m² or more, and in certain large venues, hospitals and leisure buildings.

Can a toilet open straight off a kitchen?
This one is not Part M but Part G. LABC explains that every house or flat needs at least one toilet with a handwashing facility in the room or in an adjacent room that gives the only access to it. The toilet and handwashing must be separated by a door from any kitchen or food preparation area. The purpose is basic hygiene, and a kitchen sink cannot stand in for the basin.
Approval, ventilation and who signs it off
When a renovation does need building control, ventilation is one of the items inspected. A guide to home ventilation solutions explains how those requirements fit with current energy standards. Plan it early, because moving a bathroom or adding an en-suite often changes drainage and extraction at the same time.
A worked example
Say you own a 2005 semi in Cardiff and want to replace the downstairs cloakroom suite and add a wet room upstairs.
- The cloakroom is the ground-floor WC designed for visiting wheelchair users. Replacing the suite like for like is fine. Shrinking the room or narrowing the door would make it less accessible, so it should not be done.
- The upstairs wet room is a refit of an existing bathroom. It generally does not need approval, unless drainage or electrical work is involved.
- If you add a new en-suite in a bedroom, assume approval is needed.
Perspective
Most customers ask us about Part M expecting a list of rules they must pass. The reality in Welsh homes is calmer: keep the ground-floor WC as accessible as it was, and get approval where drainage, electrics or a brand-new bathroom are involved.
The better question is how the room will serve you in ten or twenty years. We would rather plan a level-access shower, solid wall backing for future rails and a door that opens outwards while the walls are open than retrofit them later. We deliver bathrooms as one accountable local team with fixed pricing, so those decisions are made once, in the design, not discovered halfway through the job.
James
Planning your bathroom with us
Our bathroom renovation service in Cardiff is published from 2500-4000 GBP one-off. We handle bathroom installation, wet rooms, en-suites and cloakrooms, plumbing and tiling as one local team, with 25 verified 5-star Google reviews. For a wheelchair-friendly layout, our guide to wheelchair bathroom layout covers sizes and clearances. If you are in the Vale, see our bathroom fitters in Barry page, or visit the JM Plumbing Services homepage for wet rooms and WC installations.

FAQ
Does Part M apply when I refit my bathroom in Wales?
Generally not. Approved Document M does not apply to material alterations of an existing dwelling, but the work must not leave the home less accessible than before. Drainage or electrical work in the refit may still need approval.
What size is a Part M accessible toilet?
A wheelchair-accessible unisex toilet is 2200 mm deep × 1500 mm wide with a 1500 × 1500 mm turning space. If it is the only toilet in a building, the width rises to 2000 mm. These figures apply to non-domestic buildings.
Can I remove my downstairs toilet?
If the house was built after 1999, its ground-floor WC was designed for visiting wheelchair users. GOV.WALES says it should not be removed or made less accessible in a re-fit. Contact your local authority building control before altering it.
Is a pull cord a legal requirement in a home bathroom?
No requirement for private home bathrooms is set out in the guidance we reviewed. Alarm cords are a feature of accessible toilets in public and non-domestic buildings, and are worth considering at home for someone with limited mobility.
Sources
- Approved Document M, Wales
- GOV.WALES: kitchens and bathrooms
- GOV.WALES: ground-floor WCs
- GOV.UK: Approved Document M
- Approved Document M Volume 1 (2015, 2016 amendments)
- Approved Document M Volume 1, wheelchair dwellings
- Accessible toilet dimensions
- Accessible WC Calculator
- East Sussex Building Control: accessible toilets
- Top BC: accessible toilets
- BBC News report, February 2025
- Approved Document M Volume 2, 2024 amendments
- Wales amendments to Approved Document M, 2023
- LABC: Is one sink ever enough?
- Home ventilation solutions